ATHENA LATEX EXAM GLOVES
Medical gloves provide protection from unwanted and dangerous substances for both healthcare professionals and patients.
ATHENA GLOVE™ LATEX EXAM GLOVES
Meet the essential needs of gloves user and exceed international product standards to provide uncompromising protection.
ATHENA GLOVE™ LATEX EXAM GLOVES
Made with natural rubber as the key ingredient, obtaining proper protection and prevention, comfort, natural feel, and enhanced protection from viruses & bacteria with superior strength & durability. Dexterous and secure handling of instruments. Excellent elasticity and second skin feeling.
Type: Powder-free, non-sterile
Primary Material: Natural Rubber
Powder: No powder Lubricant added
Color: Natural White
Design and Feature: Ambidextrous, Smooth, Textured surface at fingers and breaded cuff
Packing: 100 gloves per dispenser box by weight, 10 boxes per carton (Small to Extra-Large)
Dimension Inner Box: W120 x L220 x H70 mm
Dimension Outer Carton: W245 x L365 x H225 mm
Type: Powder-free, non-sterile
Primary Material: Natural Rubber
Powder: No powder Lubricant added
Color: Natural White
Design and Feature: Ambidextrous, Smooth, Textured surface at fingers and breaded cuff
Packing: 100 gloves per dispenser box by weight, 10 boxes per carton (Small to Extra-Large)
Dimension Inner Box: W120 x L220 x H70 mm
Dimension Outer Carton: W245 x L365 x H225 mm
Dimensions
Glove Size | Palm Width (mm) | Length (mm) | Weight (g) |
---|---|---|---|
Small | 84 ± 3 | min.240 | 4.85 ± 0.3 |
Medium | 94 ± 3 | min.240 | 5.50 ± 0.3 |
Large | 104 ± 3 | min.240 | 5.70 ± 0.3 |
Extra-Large | 113 ± 3 | min.240 | 6.40 ± 0.3 |
Thickness
Location of Thickness Measurements | Single Wall (mm) |
---|---|
Finger (at 15 mm from the extreme tip) | min.0.08 |
Palm (at center of palm) | min.0.08 |
Cuff (at 25 mm from cuff end) | min.0.08 |
Physical Properties
Parameters | Before Aging | After Aging |
---|---|---|
Tensile Strength (MPa) | min. 6 | min. 6 |
Elongation (%) | min. 500 | min. 400 |
EN 455-2 Force At Break (N) | min. 6 | min. 6 |
Pre-shipment Quality Inspection
Criteria | Insp. Level | AQL |
---|---|---|
Dimension | N=13 | Median |
Physical Properties | N=13 | Median |
1000ml Water Leak Test | G-l | 1.5 |
Visual Inspection for Major Defects | G-l | 2.5 |
Visual Inspection for Minor Defects | G-l | 4.0 |
Powder Free Residue | N=5 | N/A |
Product Conformance
- Food Safe US FDA 21 CFR 177.2600 (Test Report)
- CE EN ISO 21420:2020 (Protective Gloves-General requirements and test methods)
- CE EN 374-5:2016 (Micro-Organisms Resistant), PPE Regulation EU(2016/425)
- EN 455 Parts 1,2,3 Medical Device Regulation (Test Report)
- Personal Protective Equipment of Complex Design Category ll, type tested to EN 374-1, EN 374-2:2014, ISO 3071:2020, ISO 14362-1:2017, ISO/TS 16186:2012, ISO/TS 16190:2013, ASTM F2517-15, ISO TS 16181:2011
- ASTM D3578-05 Standard Specification for Rubber Examination Gloves (Test Report)
Quality Assurance
- Thailand FDA
- ISO9001 Quality Management System (QMS)
- ISO14001 Environmental Management System (ASQ)
Cautions
- This product contains natural rubber which may cause allergic reactions in some individuals.
- Not applicable for electrical use, protecting ionizing radiation, flames and temperature at minus or over 100 °C.
Shelf Life
- 3 Years in cool, covered condition, exterior exposure to direct sunlight will reduce shelf life and will result in fading, discoloration and cracking.